Computational protocol: Is the Poly (L- Lactide- Co– Caprolactone) Nanofibrous Membrane Suitable for Urinary Bladder Regeneration?

Similar protocols

Protocol publication

[…] The surface of nanomaterial was modified by treatment with a 0.5 M solution of sodium bicarbonate dissolved in deionized water. Filter paper was soaked with a treatment solution and placed on top of the membrane for 30 min. The results were measured using a goniometric method by measuring contact angle of 2 µl droplet of water placed on a membrane before and after modification (OCA 20, DataPhysics Instruments GmbH, Filderstad, Germany). ImageJ software (NIST, USA) was used to evaluate data. [...] Statistical differences between groups were determined by one-way ANOVA followed by Tamhane' post hoc multiple-comparison test (IBM SPSS Statistics, Predictive Solutions, Poland). Statistically significant differences were defined as having p<0.05. […]

Pipeline specifications

Software tools ImageJ, SPSS
Databases OCA
Applications Miscellaneous, Microscopic phenotype analysis
Organisms Rattus norvegicus