CytExpert statistics

info info

Citations per year

Number of citations per year for the bioinformatics software tool CytExpert
info

Tool usage distribution map

This map represents all the scientific publications referring to CytExpert per scientific context
info info

Associated diseases

This word cloud represents CytExpert usage per disease context
info

Popular tool citations

chevron_left Data acquisition chevron_right
Want to access the full stats & trends on this tool?

Protocols

CytExpert specifications

Information


Unique identifier OMICS_30185
Name CytExpert
Software type Application/Script
Interface Graphical user interface
Restrictions to use None
Operating system Windows
Computer skills Medium
Version 2.1
Stability Stable
Registration required Yes
Maintained Yes

Versioning


No version available

Maintainer


  • person_outline CytExpert Team

CytExpert citations

 (55)
library_books

Cavitation threshold Determination and Rheological parameters Estimation of Albumin stabilized Nanobubbles

2018
Sci Rep
PMCID: 5945894
PMID: 29748624
DOI: 10.1038/s41598-018-25913-8

[…] based on the size of the standard beads in the range from 200 to 1000 nm for determining the size of our fabricated albumin NBs. The acquired violet-SS signals of the albumin NBs were analyzed using CytExpert analysis software version 2.0 (Beckman Coulter, CA). […]

library_books

Endoplasmic reticulum stress induced apoptosis in intestinal epithelial cells: a feed back regulation by mechanistic target of rapamycin complex 1 (mTORC1)

2018
PMCID: 5932775
PMID: 29744053
DOI: 10.1186/s40104-018-0253-1

[…] lowed with Annexin V-FITC and PI staining at room temperature for 15 min. Flow cytometric analysis was performed using a CytoFLEX flow cytometer (Beckman Coulter, USA), and data were collected by the CytExpert software (version 1.2). The percentages of apoptotic cells at early phase plus late phase were used for statistical analysis. […]

call_split

Ionizing Radiation Induces Morphological Changes and Immunological Modulation of Jurkat Cells

2018
Front Immunol
PMCID: 5936756
PMID: 29760710
DOI: 10.3389/fimmu.2018.00922
call_split See protocol

[…] uman CD25 clone 2A3, Becton Dickinson) and subjected to multicolor flow cytometry using a CytoFlexS cytometer (Beckman Coulter, Krefeld, Germany). Data acquisition and analysis were accomplished with CytExpert Version 1.2 software (Beckman Coulter). […]

call_split

Differential Interaction of Platelet Derived Extracellular Vesicles with Leukocyte Subsets in Human Whole Blood

2018
Sci Rep
PMCID: 5920058
PMID: 29700367
DOI: 10.1038/s41598-018-25047-x
call_split See protocol

[…] µl/min. To avoid carry-over effects, a 2 min washing step with sterile filtered double distilled water was performed between each measurement at a flow rate of 60 µl/min. Data were analyzed using the CytExpert Software Version 1.2 (Beckman Coulter). Buffer controls and fluorochrome labeled reagent controls are shown in Supplementary Fig. . The release of EVs during storage of whole blood and PFP w […]

library_books

Pathogen Specific Binding Soluble Down Syndrome Cell Adhesion Molecule (Dscam) Regulates Phagocytosis via Membrane Bound Dscam in Crab

2018
Front Immunol
PMCID: 5915466
PMID: 29720978
DOI: 10.3389/fimmu.2018.00801

[…] shed with PBS three times. Subsequently, the phagocytosis rate in 1 ml of each sample was determined by flow cytometry using a CytoFLEX flow cytometry (Beckman, USA), and the data were analyzed using CytExpert software. Ten thousand hemocytes were counted for each sample, which was from three crab. The experiments were repeated three times. […]

library_books

Endocycle related tubular cell hypertrophy and progenitor proliferation recover renal function after acute kidney injury

2018
Nat Commun
PMCID: 5890293
PMID: 29632300
DOI: 10.1038/s41467-018-03753-4

[…] d with AQP2 pAb (bs-4611R, dilution 1:20, Bioss Inc.) followed by an Alexa Fluor 647 goat anti-rabbit as secondary antibody and then analyzed by Cytoflex S instrument (Beckman Coulter, Brea, CA) with CytExpert software. AQP2-depleted cell fraction was fixed with 70% ethanol overnight and the day after was stained with anti-DsRed pAb (632496, dilution 1:25, Clontech) and anti-GFP pAb (A21311, dilut […]


Want to access the full list of citations?
CytExpert institution(s)
Beckman Coulter, Life Sciences Division Headquarters, Indianapolis, IN, USA

CytExpert reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review CytExpert