Datasqueeze statistics

info info

Citations per year

info

Popular tool citations

chevron_left Data analysis chevron_right
info

Tool usage distribution map

Tool usage distribution map
info info

Associated diseases

Associated diseases
Want to access the full stats & trends on this tool?

Datasqueeze specifications

Information


Unique identifier OMICS_26593
Name Datasqueeze
Software type Application/Script
Interface Graphical user interface
Restrictions to use License purchase required
Operating system Unix/Linux, Mac OS, Windows
Programming languages Java
Computer skills Medium
Version 3.0
Stability Stable
Free trial Yes
Maintained Yes

Versioning


No version available

Maintainer


  • person_outline Paul Heiney

Datasqueeze citations

 (7)
library_books

The effect of crystallite size on pressure amplification in switchable porous solids

2018
Nat Commun
PMCID: 5910435
PMID: 29679030
DOI: 10.1038/s41467-018-03979-2

[…] beam with dimensions of 0.5 × 0.5 mm was used for the experiments. corundum powder with a crystallite size of 5 µm was used as an external standard. the image frames were integrated using datasqueeze 2.2.9 software and processed using fityk 0.9.8 program. the pxrd patterns measured at defined points of the nitrogen physisorption isotherm are shown in supplementary fig. –. for sample […]

library_books

X ray physico chemical imaging during activation of cobalt based Fischer–Tropsch synthesis catalysts

2017
Philos Trans A Math Phys Eng Sci
PMCID: 5719219
PMID: 29175905
DOI: 10.1098/rsta.2017.0057

[…] per point was 500 ms and each xrd–ct scan lasted approximately 45 min (inclusive stage movement and detector read-out time). powder ring data were obtained and these were radially integrated (using datasqueeze software) after calibrating the detector and its response with an 8 nm ceo2 standard (http://www.datasqueezesoftware.com/index.html). for each observed intensity in these radially […]

library_books

Processing two dimensional X ray diffraction and small angle scattering data in DAWN 2

2017
J Appl Crystallogr
PMCID: 5458597
PMID: 28656043
DOI: 10.1107/S1600576717004708

[…] of software packages that can deal with two-dimensional data sets, fit2d (hammersley et al., 1996; hammersley, 2016) is the most well known. more recent software developments can be proprietary (datasqueeze 3.0; heiney, 2005) or open source but written in expensive commercial languages (nika; ilavsky, 2012). in contrast to this are open-source developments using freely available languages, […]

library_books

Macromolecular Interactions Control Structural and Thermal Properties of Regenerated Tri Component Blended Films

2016
Int J Mol Sci
PMCID: 5187789
PMID: 27916801
DOI: 10.3390/ijms17121989

[…] in a vacuum for 24 h, before x-ray collection. the intensity reported is not absolute intensity and is, thus, reported in arbitrary units (a.u.). the x-ray scattering profiles were evaluated using datasqueeze software; the isotropic 2-d scattering patterns were azimuthally integrated to yield an intensity versus scattering vector. for pure samples, the background was subtracted from an empty 1 […]

library_books

A molecular nematic liquid crystalline material for high performance organic photovoltaics

2015
Nat Commun
PMCID: 4309440
PMID: 25586307
DOI: 10.1038/ncomms7013

[…] to the incoming x-ray beam (~0.18°). the scattering intensity was detected on a 2d image plate (mar345) with a pixel size of 100 μm (3,450 × 3,450 pixels). data analysis was performed using the datasqueeze 3.0.0 software. atomic force microscopy images were acquired using an asylum research cypher scanning probe microscope operated in tapping mode. samples for electron microscopy […]

library_books

Low temperature enantiotropic nematic phases from V shaped, shape persistent molecules

2009
Beilstein J Org Chem
PMCID: 2839554
PMID: 20300458
DOI: 10.3762/bjoc.5.73

[…] and a bruker detector (high-star) with 1024 × 1024 pixels. the diffraction data were calibrated by using silver behenate as a calibration standard []. the x-ray patterns were evaluated using the datasqueeze software (http://www.datasqueezesoftware.com/)., the mixture of 1.0 equiv of thiadiazole 7, 1.0 equiv of the corresponding terminal alkyne 6a–e, 0.1 equiv of pd(pph3)4 and 0.05 equiv […]


Want to access the full list of citations?

Datasqueeze reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review Datasqueeze