FIELD II statistics

Tool stats & trends

Looking to identify usage trends or leading experts?

FIELD II specifications

Information


Unique identifier OMICS_26095
Name FIELD II
Software type Application/Script
Interface Command line interface
Restrictions to use None
Operating system Unix/Linux, Mac OS, Windows
Programming languages MATLAB
Computer skills Advanced
Version 3.24
Stability Stable
Maintained Yes

Download


download.png
download.png
download.png

Versioning


No version available

Documentation


Maintainer


  • person_outline Jorgen Jensen

Additional information


https://field-ii.dk/?field_II_pro.html

Publications for FIELD II

FIELD II citations

 (28)
library_books

Imaging beyond ultrasonically impenetrable objects

2018
Sci Rep
PMCID: 5893560
PMID: 29636513
DOI: 10.1038/s41598-018-23776-7

[…] s, Natick, MA, USA). The acoustic pressure field corresponding to the calculated phase and apodization maps was simulated using a Matlab code based on the angular spectrum approach and verified using Field II software. Both programs run on a Dell OptiPlex 7040 PC with a Windows 10 Enterprise 64-bit operating system, Intel® Core™ i7-6700 processor, 3.40 GHz, 16 GB RAM. Ultrasound imaging was perfor […]

library_books

Digital Path Approach Despeckle Filter for Ultrasound Imaging and Video

2017
PMCID: 5651154
PMID: 29118965
DOI: 10.1155/2017/9271251

[…] 50 frames subjected to different transformations that simulate the possible displacements during the ultrasound acquisition process. Then, all the frames have been subjected to a simulation using the Field II application. Virtually noise-free reference video was obtained by averaging of 200 simulation results (reference videos could be downloaded from http://dip.aei.polsl.pl/usg/fetus_video.7z). […]

library_books

An Assessment of Iterative Reconstruction Methods for Sparse Ultrasound Imaging

2017
PMCID: 5375819
PMID: 28282862
DOI: 10.3390/s17030533

[…] s for medical ultrasound imaging, as in [,], in order to allow image reconstruction by the IPB approach, as proposed in this study.In the experiments presented in this paper, matrix H was built using Field II software package [,], running on MATLAB® (The MathWorks Inc., Natick, MA, USA) environment. […]

library_books

Eigenspace based beamformer using oblique signal subspace projection for ultrasound plane wave imaging

2016
Biomed Eng Online
PMCID: 5122033
PMID: 27881172
DOI: 10.1186/s12938-016-0244-4

[…] Field II software [, ], was used to simulate the plane wave imaging for a linear array with 128 elements spaced at one-half wavelength (element width = 92.4 µm, height = 5 mm, kerf = 61.6 µm). The cen […]

library_books

Effects of Non Elevation Focalized Linear Array Transducer on Ultrasound Plane Wave Imaging

2016
PMCID: 5134565
PMID: 27845751
DOI: 10.3390/s16111906

[…] between EFT and NEFT is shown in ). To answer this question, comparison was first made between the images obtained by the simulated NEFT and EFT transducers on two simulated phantoms using Matlab and Field II []. Then a NEFT probe was fabricated together with an EFT using the same parameters. Their acoustic fields in transmission were acquired using a 3-D acoustic field measurement system and exam […]

library_books

A combination of parabolic and grid slope interpolation for 2D tissue displacement estimations

2016
PMCID: 5544786
PMID: 27837312
DOI: 10.1007/s11517-016-1593-7

[…] Ultrasound cine loops of three types of objects were used: a simulated object, a phantom object, and the far wall of the common carotid artery in vivo.Ultrasound simulations were created using Field II [, ] running under MATLAB R2013a (The MathWorks, Inc., Natick, MA, USA). The settings used in the simulations are presented in Table . The in silico model consisted of a body of scatterers wi […]

Citations

Looking to check out a full list of citations?

FIELD II institution(s)
Department of Information Technology, Technical University of Denmark, Lyngby, Denmark

FIELD II reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review FIELD II