FLUKA statistics

To access cutting-edge analytics on consensus tools, life science contexts and associated fields, you will need to subscribe to our premium service.

Subscribe
info

Citations per year

Citations chart
info

Popular tool citations

chevron_left Clinical simulation chevron_right
Popular tools chart
info

Tool usage distribution map

Tool usage distribution map
info

Associated diseases

Associated diseases

FLUKA specifications

Information


Unique identifier OMICS_23143
Name FLUKA
Software type Package/Module
Interface Command line interface
Restrictions to use None
Operating system Unix/Linux
License FLUKA user license
Computer skills Advanced
Stability Stable
Maintained Yes

Download


Versioning


Add your version

Documentation


Additional information


http://www.slac.stanford.edu/pubs/slacreports/reports16/slac-r-773.pdf

Publication for FLUKA

FLUKA in publications

 (6)
PMCID: 5345066
PMID: 28281679
DOI: 10.1038/srep43910

[…] al foil and placed 7.8 cm from the nozzle at a 38° angle from the laser axis. the maximum and average single-shot dose are 47 gy and 27 gy respectively. the corresponding charge is calculated using fluka, a particle physics monte carlo simulation package, obtaining about 5 nc per shot. as these measurements only cover about a quarter of the beam, a 21 × 17.5 cm2 gafchromic film is placed 4 cm […]

PMCID: 5302944
PMID: 27494855
DOI: 10.18632/oncotarget.10996

[…] (l) dependence was statistically preferable in describing the experimental data in the examined dose range. moreover, predictions of the cell survival data have been performed applying the mc code fluka and hit re-implementation of the gsi lem-iv model (solid lines in figure ). the experimentally obtained and model-based values for rbe at 30% survival (rbe30) are reported in table […]

PMCID: 4928842
PMID: 27362656
DOI: 10.1371/journal.pone.0157627

[…] an absorption process so if it occurs, the neutron history will be terminated. the procedures described above are programed in fortran90 and executed., we benchmarked our monte carlo code with the fluka code [,] (http://www.fluka.org) by comparing the proton energy distributions for three different pe layer thicknesses of 0.1, 1 and 5 cm for neutron energies of 1 and 10 mev. the endf library […]

PMCID: 4796019
PMID: 27047796
DOI: 10.3389/fonc.2016.00062

[…] detector sensitive volume and experimental setup uncertainties. for qa measurements in reference conditions, the applied acceptance threshold is 5% for both mean deviation and sd over a data set., fluka is a multipurpose mc transport code originally designed for high-energy physics but with extensive use in medical applications (, ). for the purpose of this paper, the hadrotherapy suite […]

PMCID: 4707204
PMID: 26793617
DOI: 10.3389/fonc.2015.00297

[…] for this purpose, precise modeling of the irradiation system and reliable computational platforms are needed. at the heidelberg ion therapy center (hit), the beamline has been already modeled in the fluka monte carlo (mc) code. however, this model was kept confidential for disclosure reasons and was not available for any external team. the main goal of this study was to create efficiently phase […]


To access a full list of publications, you will need to upgrade to our premium service.

FLUKA institution(s)
European Laboratory for Particle Physics (CERN), Geneva, Switzerland; ELI Beamlines, Harfa Office Park Ceskomoravska, Prague, Czech Republic; Unita di Fisica Medica, Fondazione CNAO, Pavia, Italy; Istituto Nazionale di Fisica Nucleare, Sezione di Milano, Milano, Italy
FLUKA funding source(s)
Supported by ENVISION, which is co-funded by the European Commission under FP7 Gr. Agreement N. 241851.

FLUKA reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review FLUKA