Genedata Screener statistics

To access cutting-edge analytics on consensus tools, life science contexts and associated fields, you will need to subscribe to our premium service.

Subscribe
info

Citations per year

Citations chart
info

Popular tool citations

chevron_left Data analysis Drug combination analysis chevron_right
Popular tools chart
info

Tool usage distribution map

Tool usage distribution map
info

Associated diseases

Associated diseases

Genedata Screener specifications

Information


Unique identifier OMICS_11595
Name Genedata Screener
Software type Application/Script
Interface Graphical user interface
Restrictions to use License purchase required
Operating system Unix/Linux, Mac OS, Windows
License Commercial
Computer skills Medium
Stability Stable
Maintained Yes

Versioning


Add your version

Maintainer


  • person_outline Genedata Screener <>

Genedata Screener in publications

 (41)
PMCID: 5958115
PMID: 29773803
DOI: 10.1038/s41467-018-04261-1

[…] eq. 2: z′-factor = 1–3 × (sd0% + sd100%)/(mean100% − mean0%); eq. 3: signal-to-background (s/b) ratio = mean100%/mean0%. activities of all tested compounds were registered with their compound id by genedata screener (genedata, basel, switzerland) and pipeline pilot software (accelrys, san diego, ca, usa). hits, cherry-picked from a separate stock dose-dependent activity test, were selected […]

PMCID: 5913971
PMID: 29339392
DOI: 10.1128/AAC.01505-17

[…] and acquisition of one microscopic field per well. images were processed using hcs studio scan software, and the selected-object count (hct-8 cells) and spot count (c. hominis) were analyzed in genedata screener (version 13.0; standard). dose-response curves and ec values were calculated using the smart fit function of genedata analyzer., excysted c. parvum oocysts were added to >90% […]

PMCID: 5833477
PMID: 29416006
DOI: 10.1038/s41419-017-0202-5

[…] (st. louis, mo, usa). all compounds were dissolved in dmso (10 mm) and stored at −20 °c., normalization, quality control, and fitting curves for ic50 determination of tested compounds were done with genedata screener® for high-content screening and genedata condoseo modules (genedata ag, basel, switzerland). in detail, wells with a reduced cell number >50% compared to dmso control were masked […]

PMCID: 5789920
PMID: 29311306
DOI: 10.1073/pnas.1713701115

[…] ic50 values were calculated by fitting dose–responses to four-parameter hill equation using graphpad prism with constrained bottom at 0 and top at 1. for high-throughput screen data analysis, the genedata screener was used., we thank saundra clausen, jennifer perry-ruzic, rebecca turincio, timothy dawes, margaret scott, cristina lewis, moulay hicham alaoui ismaili, and other colleagues […]

PMCID: 5741634
PMID: 29273768
DOI: 10.1038/s41467-017-02332-3

[…] with 4% formaldehyde, stained with 0.01% hoechst 33324, and then sealed and read on with pherastar fs hts microplate reader (bmg labtech). a saline-only plate was used to control background signals. genedata screener software (genedata, inc. basel, switzerland) was used to process and analyze the results. for each plate, the raw fluorescence gfp values were normalized with corresponding hoechst […]


To access a full list of publications, you will need to upgrade to our premium service.

Genedata Screener institution(s)
Genedata, Basel, Switzerland

Genedata Screener reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review Genedata Screener