ImageQuest statistics

info info

Citations per year

info

Popular tool citations

chevron_left Image visualization Image mapping Data format conversion Image acquisition chevron_right
info

Tool usage distribution map

Tool usage distribution map
info info

Associated diseases

Associated diseases
Want to access the full stats & trends on this tool?

ImageQuest specifications

Information


Unique identifier OMICS_05665
Name ImageQuest
Software type Toolkit/Suite
Interface Graphical user interface
Restrictions to use License purchase required
Operating system Unix/Linux
License Commercial
Computer skills Medium
Stability No
Maintained No

Versioning


No version available

ImageQuest citations

 (20)
library_books

Visualization of Mycobacterial Biomarkers and Tuberculosis Drugs in Infected Tissue by MALDI MS Imaging

2018
PMCID: 5956283
PMID: 29668262
DOI: 10.1021/acs.analchem.8b00985

[…] acquired in negative polarity across the mass range of m/z 500–2000 with a laser energy of 20 μj and five shots per position (one microscan per position)., 2d ion images were generated using thermo imagequest software (v1.01). normalized ion images of rif were generated by dividing the rif [m – h]− signal (m/z 821.397 ± 0.003) by the rif-d3 [m – h]− signal (m/z 824.416 ± 0.003). normalized ion […]

library_books

Spatial temporal profiling of prodiginines and serratamolides produced by endophytic Serratia marcescens harbored in Maytenus serrata

2018
PMCID: 5869619
PMID: 29588473
DOI: 10.1038/s41598-018-23538-5

[…] collisional dissociation (hcd) with 45 ev and a resolution of 35 000 @ m/z 200. data processing and mapping of mass pixels corresponding to the target compounds was done with the software package imagequest (v. 1.1.0; thermo fisher scientific, germany). ion images were generated with a bin width of ± 2.0 ppm for full scans and ± 3.0 ppm for ms2 experiments. the mass pixels are shown as false […]

library_books

Unraveling Drug Penetration of Echinocandin Antifungals at the Site of Infection in an Intra abdominal Abscess Model

2017
PMCID: 5610477
PMID: 28739797
DOI: 10.1128/AAC.01009-17

[…] size at which small necrotic areas within lesions could easily be resolved, and no overlapping of the laser spot on adjacent acquisitions was observed., data visualization was performed using thermo imagequest software. normalized ion images of cd101 were generated by dividing cd101 [m+h]+ signal (m/z 1,225.603 ± 0.005) by cd101-d9 [m+h]+ signal (m/z 1,234.651 ± 0.005). normalized ion images […]

library_books

Ethambutol Partitioning in Tuberculous Pulmonary Lesions Explains Its Clinical Efficacy

2017
PMCID: 5571334
PMID: 28696241
DOI: 10.1128/AAC.00924-17

[…] 1 microscan per position). the laser step size was set at 50 μm, which enabled small necrotic areas within lesions to be resolved without overlap of the laser spot on adjacent acquisitions. thermo imagequest software (version 1.01) was used to reconstruct two-dimensional (2d) ion images. normalized ion images of emb were generated by dividing emb [m+h]+ signal (m/z 205.193 ± 0.003) by emb-d10 […]

library_books

Comparing efficacies of moxifloxacin, levofloxacin and gatifloxacin in tuberculosis granulomas using a multi scale systems pharmacology approach

2017
PMCID: 5560534
PMID: 28817561
DOI: 10.1371/journal.pcbi.1005650

[…] at which small necrotic areas within granulomas could easily be resolved and no overlapping of the laser spot on adjacent acquisitions was observed., data visualization was performed using thermo imagequest software. normalized ion images of mxf were generated by dividing mxf [m+h]+ signal (m/z 402.182 ± 0.003) by mxf-d3 [m+h]+ signal (m/z 405.201 ± 0.003). normalized ion images of gfx […]

library_books

Lipid zonation and phospholipid remodeling in nonalcoholic fatty liver disease

2017
PMCID: 5396354
PMID: 27863448
DOI: 10.1002/hep.28953

[…] components loadings were normalized according to their contribution to the overall variation before computing averages from different experiments. multi‐ion image overlays were produced using imagequest software (thermo fisher scientific)., unless stated otherwise, data are reported as the mean ± standard error of the mean. statistical significance was evaluated using analysis of variance […]


Want to access the full list of citations?

ImageQuest reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review ImageQuest