Mass-Up statistics

To access cutting-edge analytics on consensus tools, life science contexts and associated fields, you will need to subscribe to our premium service.

Subscribe
info

Citations per year

Citations chart
info

Popular tool citations

chevron_left Peak alignment Peak detection All-in-one tools chevron_right
Popular tools chart
info

Tool usage distribution map

Tool usage distribution map
info

Associated diseases

Associated diseases

Mass-Up specifications

Information


Unique identifier OMICS_10642
Name Mass-Up
Software type Package/Module
Interface Graphical user interface
Restrictions to use None
Operating system Unix/Linux, Mac OS, Windows
Programming languages Java
License GNU General Public License version 2.0
Computer skills Medium
Stability Stable
Requirements
Mass-Up
Maintained Yes

Versioning


Add your version

Maintainer


  • person_outline Miguel Reboiro-Jato <>

Publication for Mass-Up

Mass-Up in publications

 (129)
PMCID: 5916508
PMID: 29707636
DOI: 10.1126/sciadv.aar2632

[…] (dsc) provided critical information about the amount of water delivered by impact and the reservoirs of that water. tg profiles of the heat-treated pumice target show that the pumice gradually loses mass up to a temperature of 850°c (fig. s1). mass loss continues above 190°c, which is the temperature at which the silica surface completely dehydrates (). therefore, this profile is consistent […]

PMCID: 5868190
PMID: 29599963
DOI: 10.1093/jscr/rjy040

[…] adrenal gland was resected as a single unit in order to avoid the risk of tumor rupture. a short sub-costal laparotomy, necessary to extract the tumor, was performed to make it possible to lift the mass up by placing one hand in the wound, with the wall being protected by a plastic retractor ring. the postoperative period was straightforward, with the patient taking food the next day, […]

PMCID: 5862848
PMID: 29563501
DOI: 10.1038/s41467-018-03511-6

[…] on 4–12% bis-tris gels using 1 × mops running buffer at 200 v. the sds-page gel was stained with simplyblue safestain (thermofisher scientific) and bands excised in 10 gel regions from the 10 kda mass up to the loading edge of the gel, for each sample. gel bands were washed with 50 mm ammonium bicarbonate (ambic)/50% acn solution for 15 min with mild shaking. they were further dehydrated […]

PMCID: 5837429
PMID: 29511734
DOI: 10.1126/sciadv.aao1761

[…] the typical loading of active materials is ~2.5 mg cm−2, leading to the areal capacity of ~0.8 mah cm−2 and zinc utilization of ~4% (fig. s13). the capacity still remains about 90% at the loading mass up to 10 mg cm−2, at which point the zinc utilization increases to 15% (fig. s14). the nafion membrane was initially soaked in the electrolyte over 1 day before use. after soaking, the zinc […]

PMCID: 5823330
PMID: 29460728
DOI: 10.3201/eid2403.170459

[…] 2 spots and analyzed each spot 3 times, resulting in 6 spectra/isolate. isolates in the reference database were spotted on 8 spots, resulting in 24 spectra, before being added to the database., in mass-up 1.0.13 (), we preprocessed and analyzed raw spectra of all isolates in the evaluation set (n = 258) and capsule transformants (n = 4) by using the integrated maldiquant analysis package for r […]


To access a full list of publications, you will need to upgrade to our premium service.

Mass-Up institution(s)
Informatics Department, Universidad de Vigo, Campus Universitario As Lagoas s/n, Ourense, Spain; Instituto de Investigación Biomédica de Vigo (IBIV), Vigo, Pontevedra, Spain; BIOSCOPE Research Group, UCIBIO-REQUIMTE, Department of Chemistry, Faculty of Science and Technology, Universidade NOVA de Lisboa, Caparica, Setubal, Portugal

Mass-Up reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review Mass-Up