NuclearQuant module specifications

Information


Unique identifier OMICS_25778
Name NuclearQuant module
Software type Package/Module
Interface Graphical user interface
Restrictions to use None
Operating system Windows
Computer skills Medium
Stability Stable
Requirements
QuantCenter
Maintained No

Versioning


Add your version

Documentation


Maintainer


This tool is not available anymore.

NuclearQuant module in publications

 (4)
PMCID: 5786000
PMID: 29374244
DOI: 10.1038/s41598-018-20095-9

[…] to the instruction of cell death detection kit (roche, basel, switzerland), and scanned by pannoramic 250 slide scanner (3d, histech ltd., budapest, hungary). then, the tunel data were collected by nuclearquant module software (3d, histech ltd., budapest, hungary) and represented as relative counts of tunel-positive cells per unit area, ie., a ratio of tunel-positive cell percentage […]

PMCID: 5560630
PMID: 28817603
DOI: 10.1371/journal.pone.0182786

[…] scanned using a digital microscope scanner (pannoramic 250 flash, 3dhistech ltd., budapest, hungary). the number of cd4- and cd8-positive cells in tissue microarray cores was determined using the nuclearquant module of the pannoramic viewer 1.15.2 (3dhistech ltd). representative images of immunohistochemical staining for cd4 and cd8 are shown in ., all statistical analyses were performed […]

PMCID: 5398384
PMID: 27488875
DOI: 10.4143/crt.2016.215

[…] were then scanned using computer viewer software (pannoramic viewer 1.15.2, 3dhistech ltd.) and the number of cd3-, cd8-, and cd20-positive lymphocytes were counted in the tumor area using the nuclearquant module. the positive cell densities were calculated by dividing the immuno-positive cell numbers by the tumor area., the levels of the cxcl13 mrna transcripts in the ffpe tissue samples […]

PMCID: 5058668
PMID: 27121061
DOI: 10.18632/oncotarget.8798

[…] and cd69 were scanned using a digital microscopy scanner pannoramic 250 flash (3dhistech ltd., budapest, hungary). the numbers of cd8+ and cd69+ cells in tissue microarray cores were counted by the nuclearquant module of pannoramic viewer 1.15.2 (3dhistech ltd)., the tcga data portal was used to download the breast cancer data []. a total of 396 cases of breast cancer were analyzed according […]


To access a full list of publications, you will need to upgrade to our premium service.

NuclearQuant module reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review NuclearQuant module