ParaVision statistics

Tool stats & trends

Looking to identify usage trends or leading experts?

Protocols

ParaVision specifications

Information


Unique identifier OMICS_33683
Name ParaVision
Software type Application/Script
Interface Graphical user interface
Restrictions to use License purchase required
Operating system Windows
License Commercial
Computer skills Medium
Version 6.0.1
Stability Stable
Registration required Yes
Maintained Yes

Versioning


No version available

Additional information


https://www.bruker.com/fileadmin/user_upload/8-PDF-Docs/MagneticResonance/MRI/brochures/ParaVision6_Brochure.pdf

ParaVision citations

 (431)
call_split

Hexarelin treatment preserves myocardial function and reduces cardiac fibrosis in a mouse model of acute myocardial infarction

2018
PMCID: 5949285
PMID: 29756411
DOI: 10.14814/phy2.13699
call_split See protocol

[…] 4 Tesla (T) small animal MRI scanner equipped with a BGA 12S HP 660 mT/m gradient set. MRI data were acquired with an 86 mm i.d. quadrature transmit coil and a 2 × 2 phase array receive coil, running Paravision 5.1. (Bruker Biospin, Ettlingen, Germany). […]

library_books

Rechargeable lithium ion cell state of charge and defect detection by in situ inside out magnetic resonance imaging

2018
Nat Commun
PMCID: 5934497
PMID: 29725002
DOI: 10.1038/s41467-018-04192-x

[…] probe was used to collect all of the data, with a Bruker WB57 40-mm i. d. coil insert for 1H experiments. 2D 1H MRI experiments were performed using a slice-selective 2D FLASH sequence implemented in Paravision 5.1, using a hermite pulse shape with pulse duration of 1 ms, an echo time (TE) of at least 2.45 ms, repetition time (TR) of 100 ms, nominal flip angle (α) of 15°, and 12 scans for signal a […]

library_books

Annexin A5 reduces infarct size and improves cardiac function after myocardial ischemia reperfusion injury by suppression of the cardiac inflammatory response

2018
Sci Rep
PMCID: 5928225
PMID: 29712962
DOI: 10.1038/s41598-018-25143-y

[…] n cushion, which was placed underneath the thorax and connected to a gating module to monitor respiratory rate (SA Instruments, Inc., Stony Brook, NY). Image reconstruction was performed using Bruker ParaVision 5.1 software. […]

library_books

Resting state fMRI study of brain activation using low intensity repetitive transcranial magnetic stimulation in rats

2018
Sci Rep
PMCID: 5928106
PMID: 29712947
DOI: 10.1038/s41598-018-24951-6

[…] I system operating at 9.4 T (400 MHz, H-1), with an Avance III HD console, BGA-12SHP imaging gradients, an 86 mm (inner diameter) volume transmit coil and a rat brain surface quadrature receive coil. ParaVision 6.0.1 software was used to control the scanner and set the experimental tasks. Following a tri-plane scan to determine the position of the rat brain, high-resolution T2-weighted coronal ima […]

library_books

Transient Hypothyroidism During Lactation Arrests Myelination in the Anterior Commissure of Rats. A Magnetic Resonance Image and Electron Microscope Study

2018
Front Neuroanat
PMCID: 5935182
PMID: 29755326
DOI: 10.3389/fnana.2018.00031

[…] rat brain receive-only phase array coil with integrated combiner and preamplifier (no tune/no match) was used, in combination with an actively detuned transmit-only resonator (Bruker BioSpin MRI) and Paravision software (Bruker Medical).Due to the AC antero-posterior diameter (ranging from 505 μm in P8 MMIE10 to 850 μm in P365 C rats) and MRI section thickness (500 μm), selection of the optimal co […]

library_books

Altered distribution of ATG9A and accumulation of axonal aggregates in neurons from a mouse model of AP 4 deficiency syndrome

2018
PLoS Genet
PMCID: 5940238
PMID: 29698489
DOI: 10.1371/journal.pgen.1007363

[…] I data were acquired using a 14.1 T magnetic resonance microimaging system with an 89-mm vertical superconducting magnet (Bruker Spectrospin) and a Bruker Avance III NMR imaging console controlled by Paravision 5.1 software (Bruker Instruments) with a 35 mm ID actively shielded gradients. A 20 mm ID birdcage volume RF resonator was used in these experiments. 3D MR images were acquired using a stan […]

Citations

Looking to check out a full list of citations?

ParaVision institution(s)
Brucker, Madison, WI, USA

ParaVision reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review ParaVision