Plastimatch statistics

To access cutting-edge analytics on consensus tools, life science contexts and associated fields, you will need to subscribe to our premium service.

Subscribe
info

Citations per year

Citations chart
info

Popular tool citations

chevron_left Image segmentation Image segmentation chevron_right
Popular tools chart
info

Tool usage distribution map

Tool usage distribution map
info

Associated diseases

Associated diseases

Plastimatch specifications

Information


Unique identifier OMICS_21689
Name Plastimatch
Software type Application/Script
Interface Command line interface
Restrictions to use None
Operating system Windows
License BSD 3-clause “New” or “Revised” License
Computer skills Advanced
Version 1.6.4
Stability Stable
Maintained Yes

Download


Versioning


Add your version

Additional information


https://hal.archives-ouvertes.fr/hal-00755222/file/Shackleford.pdf https://gitlab.com/plastimatch/plastimatch

Plastimatch in publications

 (8)
PMCID: 5689930
PMID: 28921843
DOI: 10.1002/acm2.12189

[…] and iii for likely to be repositioned under clinical routine since noticeable torsion and head tilt impede good bone match throughout (10×). transformation matrices were applied to ctrecalc via plastimatch software. for plan recalculation in the respective tps, same isocentre coordinates, beam angles, mu, dose grid, and ct to density conversion were applied., planned and recalculated dose […]

PMCID: 5368286
PMID: 28242137
DOI: 10.1016/j.ejmp.2017.02.017

[…] density was set to air in the density override planning ct for the dose re-calculations and it was not present in the scts’ image sets., for the ɣ-evaluation, a local 3d algorithm implemented in plastimatch, with constraints of 3% dose difference (dd) and 3 mm distance to agreement (dta), and 2% dd and 2 mm dta, using the density override ct dose distribution as reference, was applied. […]

PMCID: 5171237
PMID: 27996023
DOI: 10.1038/srep38895

[…] to extend contours and doses across the 4d-ct phases, deformable image registration (dir) was performed and yielded a voxel-to-voxel map between reference (0% r-r) and remaining motion phases (plastimatch version 1.15.17). quality assurance of registration was conducted by visualization of the vector field, false color, checkerboard images, propagation of contours, and the jacobian matrix. […]

PMCID: 5373730
PMID: 28367502
DOI: 10.18383/j.tom.2016.00145

[…] section. these transforms were then applied to the phases before proceeding to the next stage., the registration of the 2 phases of a pair was performed using the open source registration software plastimatch, version 1.6.0-beta (http://plastimatch.org). the settings of the translational and rigid registration steps are shown in . for the robust procedure, the first 2 translational steps […]

PMCID: 4689810
PMID: 26734573
DOI: 10.3389/fonc.2015.00291

[…] 9)., rigid registration of reference phases of each subsequent ct was performed to mimic patient setup and alignment. then non-rigid registration was used between each 4dct motion phase using plastimatch (). for each patient, clinical target volumes (ctvs) as well as oar contours (esophagus, heart, and spinal cord) were provided by physicians of mdacc for the first weekly 4dct. lung […]


To access a full list of publications, you will need to upgrade to our premium service.

Plastimatch reviews

star_border star_border star_border star_border star_border
star star star star star

Be the first to review Plastimatch