Unique identifier OMICS_02840
Name VnmrJ
Software type Toolkit/Suite
Interface Graphical user interface
Restrictions to use License purchase required
Operating system Unix/Linux
License Commercial
Computer skills Medium
Version 4.0
Stability No
Maintained No

Versioning


Add your version

Maintainer


This tool is not available anymore.

VnmrJ in publications

 (175)
PMCID: 5951818
PMID: 29760476
DOI: 10.1038/s41467-018-04228-2

[…] operating at a field strength of 17.6 t (1h ν0 = 748.4 mhz, 11b ν0 = 240.1 mhz) with a varian 5 mm direct, broadband tunable, pfg probe. the 11b experiments were acquired using a cpmgt2 (vnmrj) pulse sequence consisting of an initial 90° pulse followed by two 180° spin-echoes (rd-90°-τ-180°-2τ-180°-τ-acquire) with a relaxation delay (rd) of 500 ms and τ-delay of 50 µs. the cpmgt2 […]

PMCID: 5934638
PMID: 29648656
DOI: 10.1093/nar/gky250

[…] time of 80 ms were acquired in 100% 2h2o. twenty different gradient strengths (2.4–59.6 g cm−1) were used in diffusion nmr experiments (dosy). nmr spectra were processed and analysed with the use of vnmrj (varian inc.) software and sparky (ucsf) software ()., noesy spectra with mixing times of 80, 150 and 200 ms were recorded to collect distance restraints for exchangeable and non-exchangeable […]

PMCID: 5863359
PMID: 29588659
DOI: 10.1186/s13068-018-1074-3

[…] an agilent dd2 700 mhz spectrometer equipped with a triple resonance hcn cold probe with a scan number of 64, relaxation delay of 1 s and acquisition time of 4.5 s. the data were obtained using vnmrj 4.0 (agilent) and analyzed with mestrenova 10.0 (mestrelab research). the hdo peak at 4.790 was used as internal standard. the change in signal intensity in the regions between 5.4 and 4.4 ppm […]

PMCID: 5951306
PMID: 29561761
DOI: 10.3390/ma11040460

[…] an adsorption balance., nuclear magnetic resonance (nmr) analysis was conducted on a varian 500 spectrometer (ca, usa), equipped with 1h/13c/15n 5 mm xyz pfg triple-resonance probe using standard vnmrj software (varian inc., palo alto, ca, usa). all of the experiments were performed with a 1h 90° pulse of 7.30 μs at 298.15 k. one-dimensional (1d) 1h spectra were collected with a sweep width […]

PMCID: 5869661
PMID: 29547559
DOI: 10.3390/nano8030170

[…] length. the echo time was set to 4 and 10 ms in two separate experiments. in total, 16 consecutive images with varied echo time were acquired for each sample. the initial analysis was performed in vnmrj 4.2 revision software (santa clara, ca, usa). the raw relaxation data points were collected from an average intensity obtained from circular region of interests (rois) and then analyzed using […]